PM Dust Monitoring System with Automatic Mist Cannon Control
Product Code: PM Dust Monitoring System with Automatic Mist Cannon Control
Price: On Request
INTELLIGENT DUST CONTROL
Automatic spraying when dust levels rise
PM dust monitoring with automatic mist cannon control
Hong Kong Misting’s PM system monitors PM2.5 and PM10 in real time, logs readings and automatically controls mist cannons on construction sites, demolition projects and industrial premises in Hong Kong.
When the dust concentration reaches the upper threshold, the controller starts the mist cannon. Once the concentration drops below the lower threshold, the cannon stops after a delay. Spraying on demand can reduce manual operation, water use and energy consumption.
Continuous dust monitoring
Maximum open-air wireless range
Chinese-language LCD
Mist cannons per controller, maximum
PRODUCT FEATURES
Monitoring and dust suppression
01 / MONITORING
Real-time PM2.5 and PM10 monitoring
The sensor continuously measures airborne particle concentrations from 0 to 1,000 μg/m³ with a resolution of 1 μg/m³.
02 / DISPLAY
7-inch Chinese-language display
View four channels at once and scroll through readings from up to 32 channels. Red text and audible and visual alarms flag readings above the threshold.
03 / AUTOMATION
Adjustable start and stop thresholds
Set separate dust thresholds for starting and stopping the mist cannons. A shutdown delay helps prevent frequent cycling.
04 / WIRELESS
Wireless control over up to 800 m
The controller can operate up to four mist cannons. In open outdoor areas, the wireless link can reach up to 800 m, reducing the need for signal cabling.
05 / DATA LOGGING
Data logging and CSV export
Store up to 131,000 readings and export them as a CSV file via USB for dust monitoring and environmental reports.
06 / OFFLINE SYSTEM
Offline operation
The system works without an internet connection, SIM card or cloud platform. The equipment is a one-off purchase with no annual software or licence fees.
HOW IT WORKS
How a dust reading starts the mist cannon
The system measures dust levels, displays and records the readings, and sends control commands to the mist cannons.
Dust sensor
Measures PM2.5 and PM10 concentrations in real time.
Controller
Receives and records readings, then compares them with the configured thresholds.
Wireless transmitter
Receives relay signals from the controller and transmits commands.
Wireless receiver
Receives commands and controls the connected mist cannon.
Mist cannon
Starts and stops spraying according to the measured dust concentration.
At or above the upper threshold
The mist cannon starts spraying automatically.
Below the lower threshold
The mist cannon stops after the configured delay.
Manual control
Site staff can start or stop the mist cannon manually as needed.
APPLICATIONS
Where the system can be used
Construction sites
Foundation works, excavation, earthworks and major infrastructure projects.
Demolition projects
Building demolition, concrete breaking and other work that generates heavy dust.
Quarries and concrete plants
Stone crushing, raw material handling and stockpile areas.
Recycling yards and cargo terminals
Bulk cargo loading and unloading, waste handling and materials storage yards.
TECHNICAL SPECIFICATIONS
PM system specifications
| Item | Specification |
|---|---|
| Model | PM |
| Particles monitored | PM2.5 / PM10 |
| Measurement range | 0–1000 μg/m³ |
| Measurement resolution | 1 μg/m³ |
| Communications interface | RS485 |
| Sensor power supply | 10–30 V DC |
| Sensor mounting pole | Optional 1.5 m pole |
| Controller mounting | Wall-mounted |
| Controller power supply | 220 V AC, 50/60 Hz |
| Controller enclosure rating | IP54 |
| Display | 7-inch Chinese-language LCD |
| Channels displayed simultaneously | 4 channels |
| Channels available for viewing | Up to 32 |
| Data storage | Up to 131,000 records |
| Data export | CSV via USB |
| Alarms | Audible and visual |
| Relay outputs | 4 volt-free relay outputs |
| Wireless transmission range | Up to 800 m in open outdoor areas |
| Receiver enclosure rating | IP65 |
| Mist cannons per controller | Up to 4 |
| Control modes | Automatic start/stop, delayed shutdown and manual control |
| Network requirements | Operates without internet access, a SIM card or a cloud platform |
| Warranty | 1 year |
Specifications are for reference. Equipment configuration, wireless range and dust suppression performance depend on site conditions and project requirements.
FREQUENTLY ASKED QUESTIONS
Installation and operation
What does the dust monitoring system measure?
It measures airborne PM2.5 and PM10 concentrations in real time. The PM system also records readings, issues audible and visual alarms and can control mist cannons automatically.
How does the system control the mist cannons?
The controller sends a wireless start command when the dust concentration reaches the upper threshold. The cannon stops after a delay once the concentration falls below the lower threshold.
Can I use the system with an existing mist cannon?
Hong Kong Misting can assess whether your existing cannon can be retrofitted. Compatibility depends on its control interface, power supply and site conditions.
How many mist cannons can one controller operate?
One controller supports up to four wireless receivers and can control up to four mist cannons.
Does the system need an internet connection?
The system operates independently without Wi-Fi, a SIM card or a cloud platform, including at outdoor sites with limited network coverage.
Can I export the monitoring data?
Yes. The controller stores up to 131,000 records and exports them as a CSV file via USB for monitoring and environmental reports.
Are there any annual fees?
The equipment is a one-off purchase with no annual software or licence fees. The quotation depends on the number of units, system configuration and installation requirements.
PROFESSIONAL DUST CONTROL SOLUTIONS
Discuss dust control for your site
Hong Kong Misting can supply and install the dust monitoring equipment, mist cannons and automatic controls for your site.
Product specifications may change as the equipment is updated.