Skip to main content

Hong Kong Misting

PM Dust Monitoring System with Automatic Mist Cannon Control

Product Code: PM Dust Monitoring System with Automatic Mist Cannon Control

Price: On Request

INTELLIGENT DUST CONTROL

Automatic spraying when dust levels rise

PM dust monitoring with automatic mist cannon control

Hong Kong Misting’s PM system monitors PM2.5 and PM10 in real time, logs readings and automatically controls mist cannons on construction sites, demolition projects and industrial premises in Hong Kong.

When the dust concentration reaches the upper threshold, the controller starts the mist cannon. Once the concentration drops below the lower threshold, the cannon stops after a delay. Spraying on demand can reduce manual operation, water use and energy consumption.

24 h
Continuous dust monitoring
800 m
Maximum open-air wireless range
7″
Chinese-language LCD
4
Mist cannons per controller, maximum

PRODUCT FEATURES

Monitoring and dust suppression

01 / MONITORING

Real-time PM2.5 and PM10 monitoring

The sensor continuously measures airborne particle concentrations from 0 to 1,000 μg/m³ with a resolution of 1 μg/m³.

02 / DISPLAY

7-inch Chinese-language display

View four channels at once and scroll through readings from up to 32 channels. Red text and audible and visual alarms flag readings above the threshold.

03 / AUTOMATION

Adjustable start and stop thresholds

Set separate dust thresholds for starting and stopping the mist cannons. A shutdown delay helps prevent frequent cycling.

04 / WIRELESS

Wireless control over up to 800 m

The controller can operate up to four mist cannons. In open outdoor areas, the wireless link can reach up to 800 m, reducing the need for signal cabling.

05 / DATA LOGGING

Data logging and CSV export

Store up to 131,000 readings and export them as a CSV file via USB for dust monitoring and environmental reports.

06 / OFFLINE SYSTEM

Offline operation

The system works without an internet connection, SIM card or cloud platform. The equipment is a one-off purchase with no annual software or licence fees.

HOW IT WORKS

How a dust reading starts the mist cannon

The system measures dust levels, displays and records the readings, and sends control commands to the mist cannons.

01

Dust sensor

Measures PM2.5 and PM10 concentrations in real time.

02

Controller

Receives and records readings, then compares them with the configured thresholds.

03

Wireless transmitter

Receives relay signals from the controller and transmits commands.

04

Wireless receiver

Receives commands and controls the connected mist cannon.

05

Mist cannon

Starts and stops spraying according to the measured dust concentration.

At or above the upper threshold

The mist cannon starts spraying automatically.

Below the lower threshold

The mist cannon stops after the configured delay.

Manual control

Site staff can start or stop the mist cannon manually as needed.

APPLICATIONS

Where the system can be used

Construction sites

Foundation works, excavation, earthworks and major infrastructure projects.

Demolition projects

Building demolition, concrete breaking and other work that generates heavy dust.

Quarries and concrete plants

Stone crushing, raw material handling and stockpile areas.

Recycling yards and cargo terminals

Bulk cargo loading and unloading, waste handling and materials storage yards.

TECHNICAL SPECIFICATIONS

PM system specifications

Item Specification
Model PM
Particles monitored PM2.5 / PM10
Measurement range 0–1000 μg/m³
Measurement resolution 1 μg/m³
Communications interface RS485
Sensor power supply 10–30 V DC
Sensor mounting pole Optional 1.5 m pole
Controller mounting Wall-mounted
Controller power supply 220 V AC, 50/60 Hz
Controller enclosure rating IP54
Display 7-inch Chinese-language LCD
Channels displayed simultaneously 4 channels
Channels available for viewing Up to 32
Data storage Up to 131,000 records
Data export CSV via USB
Alarms Audible and visual
Relay outputs 4 volt-free relay outputs
Wireless transmission range Up to 800 m in open outdoor areas
Receiver enclosure rating IP65
Mist cannons per controller Up to 4
Control modes Automatic start/stop, delayed shutdown and manual control
Network requirements Operates without internet access, a SIM card or a cloud platform
Warranty 1 year

Specifications are for reference. Equipment configuration, wireless range and dust suppression performance depend on site conditions and project requirements.

FREQUENTLY ASKED QUESTIONS

Installation and operation

What does the dust monitoring system measure?

It measures airborne PM2.5 and PM10 concentrations in real time. The PM system also records readings, issues audible and visual alarms and can control mist cannons automatically.

How does the system control the mist cannons?

The controller sends a wireless start command when the dust concentration reaches the upper threshold. The cannon stops after a delay once the concentration falls below the lower threshold.

Can I use the system with an existing mist cannon?

Hong Kong Misting can assess whether your existing cannon can be retrofitted. Compatibility depends on its control interface, power supply and site conditions.

How many mist cannons can one controller operate?

One controller supports up to four wireless receivers and can control up to four mist cannons.

Does the system need an internet connection?

The system operates independently without Wi-Fi, a SIM card or a cloud platform, including at outdoor sites with limited network coverage.

Can I export the monitoring data?

Yes. The controller stores up to 131,000 records and exports them as a CSV file via USB for monitoring and environmental reports.

Are there any annual fees?

The equipment is a one-off purchase with no annual software or licence fees. The quotation depends on the number of units, system configuration and installation requirements.

PROFESSIONAL DUST CONTROL SOLUTIONS

Discuss dust control for your site

Hong Kong Misting can supply and install the dust monitoring equipment, mist cannons and automatic controls for your site.

Product specifications may change as the equipment is updated.